Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
Commercial ada door handle height.
Door and gate hardware must.
Locks used only for security purposes and not used for normal opera tion are permitted at any height.
Door hardware mounting heights 2010 ada changes.
Thresholds at doorways shall not exceed 3 4 in 19 mm in height for exterior sliding doors or 1 2 in 13 mm for other types of doors.
Door and gate hardware.
Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
A few exceptions are included in the bill.
Effort to operate doors 8 5 pounds at exterior doors and 5 pounds at interior doors door hardware height 30 44 above floor.
Caption a new landing ramp and lever door handle provide an accessible entrance to this business.
Handles pulls panic bars door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Ada door handle height requirement the height of the door handle must be between a minimum of 34 and a maximum of 48.
Lever handle added to or in place of round door knob.
Access doors or gates in barrier walls and fences protecting pools spas and hot tubs shall be permitted to have operable parts of the release of latch on self latching devices at 54 inches.
Operate with 5 lbf maximum.
Subsection 3 4 manual door hardware states that door handles should be at a minimum height of between 0 9 and 1 0 meters from the floor surface to provide a comfortable way for wheelchair users to open a door.
Raised thresholds and floor level changes at accessible doorways shall be beveled with a slope no greater than 1 2 see 4 5 2.
Door hardware operable with a single effort without requiring ability to grasp hardware.
New landing and ramp eliminates step at entrance.
Size min 3 0 wide 32 clear when 90 open and 6 8 in height.
Landing extends 18 minimum beyond the edge of door and 60 minimum out from door.
Locks used only for security purposes and not used for normal operation are permitted at any height.
There is one notable difference between the 2003 code and 2010 code.
Door closers and door stops shall be permitted to be 78 inches minimum above the finish floor or ground.